Set-top Box Application
| |
System View | Block Diagram |
|
Terrestrial Antenna Coaxial Cable Port Protection
Problem: Short-circuit overload
A shortcircuit overload to the power supply can occur if the central pin in the coaxial cable connection to the receiver is bent or crushed against the connector during installation; it can also occur any time the user disconnects the source from the receiver.
|
| |
|
Solution: PolySwitch devices.
PolySwitch devices limit the flow of dangerously high currents during fault conditions and reset back to normal operating mode once the fault condition is removed.
|
|
| |
Problem: Transient Surge Voltages and Electrostatic Discharge (ESD)
Transient surge voltages caused by lightning strikes and equipment switching operations and also electrostatic discharge (ESD) can damage the equipment.
|
| |
|
Solution: Raychem PESD devices.
Raychem PESD, which is a low capacitance (typically 0.25pF) ESD protection device, is capable of withstanding numerous ESD transients, and is a RoHS & IEC61000-4-2 compliant device having low leakage current and low clamping voltage.
|
| |
|
Solution: Gas Discharge Tubes (GDTs).
Gas Discharge Tubes (GDTs) help protect the sensitive data transmission lines equipment by switching to a low impedance state, and diverting energy away from the equipment. Due to their low capacitance, the GDTs introduce much less signal distortion than other overvoltage protection technologies.
|
| |
Circuit Diagram / Schematic

|
|
| |
|
|
| |
Competitor Cross-reference
|
|